Datasheet: WM596 (Carlo Gavazzi Automation)

Energy Management

 

Download: PDF   ZIP
 
Specifications are subject to change without notice WM5-96DS171006
1
Class 0.2 (current/voltage)
ARM
powered
Back-lighted graph display (128x64 dots)
Bargraph indication of instantaneous power (kW)
Front size: 96x96 mm
Measurement of single phase and system instantaneous
variables: W, var, VA, PF, VLL, VLN, A
L
, A
n
, Hz, THD, ASY
VLL, ASY VLN (for all measurements max, min, dmd/AVG
and max dmd/AVG values)
Measured energies (imported/exported): kWh and kvarh
Current and voltage inputs with autoranging capability
4x4 DGT instantaneous variable read-out
4x9 DGT total energies read-out
4x9 DGT partial energies read-out
Energy measurements according to ANSI C12.20, CA 0.5,
EN62053-22 CL 0.5S and ANSI C12.1, EN62053-23 CL 2
4 total 3-phase, 48 partial 3-phase and 12 total single
phase independent energy meters to be used as sin-
gle, dual, multi-time tariff management
Display refresh rate: 10 samples/s
Harmonic distortion analysis (FFT) up to the 63
rd
harmonic
with graphic and numeric indication (current and voltage)
Harmonics source detection
Data stamping of up to 10,000 events: alarm, min,
max, digital input status, digital output status as
remote control, resets
4 independent communication ports:
optical front communication port (ANSI C12.18)
optional RS 422/485 serial port, optional RS232 + real
time clock function, optional Ethernet port
Product Description
3-phase utility grade power
quality analyzer. Particularly
recommended for the mea-
surement of the main electri-
cal variables.
Housing for panel mounting,
with optical communication
Energy Management
Modular Smart Power Quality Analyzer
Type WM5-96
MODBUS RTU and TCP, JBUS protocol, iFIX SCADA
compatibility
Real time clock function (without back-up)
Up to 12 optional digital inputs (sync function, remote
digital input control)
Up to 16 optional digital outputs (pulse, alarm, remote
control)
16 freely configurable alarms with OR/AND logic link-
able with up to 4 relay outputs and up to 16 open collec-
tor outputs
Up to 8 optional analogue outputs (+20mA, +10VDC,
+/- 5mA)
Universal power supply: 18-60VAC/VDC, 90-260 VAC/VDC
Front protection degree: IP 65, NEMA4x, NEMA12
How to order
WM5-96 see next page
port (according to the ANSI
standards), RS485/RS232 or
Ethernet communication
ports, pulse and alarm out-
puts. Parameters program-
ming and data reading by
means of Wm5Soft.
How to order
Wm5Soft
Parameters programming and data reading by means of
Wm5Soft.
Description
Part N.
Slot A
Slot B
Slot C
Slot D
Slot E
WM5-96 base with ANSI local port
AD2001
WM5-96 base without local port
AD2000
Power supply (18-60VAC/DC)
AP1021
Power supply (90-260VAC/DC)
AP1020
Measuring input (AV5: 400/690VL-L)
AQ2030
Measuring input (AV6: 120/208VL-L)
AQ2031
RS485 port (9 600 bps)
AR1034
1-port
RS485 port (115,200 bps)
AR2040
1-port
Ethernet/Internet port
AR1061
1-port
Analogue output (20mA DC)
AO2050
2-out
2-out
Analogue output (10V DC)
AO2051
2-out
2-out
2-out
2-out
Analogue output (+/-5mA DC)
AO2052
2-out
2-out
2-out
2-out
Relay output
AO1058
1-out
1-out
1-out
1-out
Relay output
AO1035
2-out
2-out
Open collector output
AO1059
1-out
1-out
1-out
1-out
Open collector output
AO1036
2-out
2-out
2-out
2-out
Open collector output
AO1037
4-out
4-out
4-out
4-out
Digital inputs
AQ1038
3-in
3-in
3-in
3-in
Digital inputs + Aux
AQ1042
3-in
3-in
3-in
3-in
RS232 port + RTC (9 600 bps)
AR1039
1-port
Modules Combination




2
Specifications are subject to change without notice WM5-96DS171006
WM5-96
Model
WM5-96 with optical port
ANSI C12.18 type
WM5-96 without optical port
AD2001
AD2000
WM5 96
WM5 96
Range code + system (measuring inputs)
400/690VL-L 1/5A (10A)
120/208VL-L 1/5A (10A)
AQ2030
AQ2031
AV5.3
AV6.3
Power supply
18-60VAC/DC power supply
90-260VAC/DC power supply
AP1021
AP1020
L
H
None
Ethernet/Internet port
Digital inputs
Digital inputs + aux
Open collector output
Open collector output
Open collector output
Relay output
Analogue output 20mADC
Analogue output 10VDC
Analogue output +/-5mA
1
3
3
4
2
1
1
2
2
2
AR1061
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO2050
AO2051
AO2052
XX
E2
D1
D2
O4
O2
O1
R1
B1
W1
B2
None
Digital inputs
Digital inputs + aux
Open collector output
Open collector output
Open collector output
Relay output
Analogue output 20mADC
Analogue output 10VDC
Analogue output +/-5mA
RS485 9600bps
RS485 115200bps
3
3
4
2
1
1
2
2
2
1
1
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO2050
AO2051
AO2052
AR1034
AR2040
XX
D1
D2
O4
O2
O1
R1
B1
W1
B2
S1
S2
None
Digital inputs
Digital inputs + aux
Open collector output
Open collector output
Open collector output
Relay output
Relay output
Analogue output 10VDC
Analogue output +/-5mA
3
3
4
2
1
1
2
2
2
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO1035
AO2051
AO2052
XX
D1
D2
O4
O2
O1
R1
R2
W1
xx
None
Digital inputs
Digital inputs + aux
Open collector output
Open collector output
Open collector output
Relay output
Relay output
Analogue output 10VDC
Analogue output +/-5mA
3
3
4
2
1
1
2
2
2
AQ1038
AQ1042
AO1037
AO1036
AO1059
AO1058
AO1035
AO2051
AO2052
XX
D1
D2
O4
O2
O1
R1
R2
W1
B2
Description
Ch
Part No.
Legend
WM5 96 AV53 H XX XX XX XX XX
Bill of material
Ordering No.
WM5 96
AV53 measuring inputs (400/690VL-L)
90-260VAC/DC power supply
Analogue output 20mA (2 channels)
RS485 serial port 9600 bps
Relay output (2 channels)
Open collector (2 channels)
RS232 port+RTC
AD2001
AQ2030
AP1020
AO2050
AR1034
AO1035
AO1036
AR1039
Example of which modules to order for:
WM5-96 AV53 H B1 S1 R2 O2 SX
B
S
L
O
T
A
S
L
O
T
C
S
L
O
T
D
S
L
O
T
Minimum modules for a basic unit on grey background
Ordering key (fully assembled instrument):
How to order WM5 96
Utility grade with optical port
RS232 + RTC (utility grade)
Revenue approval. An "instru-
ment setting" form must be prop-
erly filled up by the user.
RS232+RTC + "XU" option
Utility grade without optical port
RS232 + RTC (utility grade) with-
out optical port
1
1
1
AR1039
AR1039
AR1039
XX
SX
XU
SU
YY
SY
O
P
T
I
O
N
S
A
B
C
D
Options
(E)
Measuring
Input
(Range +
system)
Power
Supply
E
S
L
O
T
Specifications are subject to change without notice WM5-96DS171006
3
WM5-96
Number of analogue inputs
Current
1 (1-phase; system code: 3)
3 (3-phase; system code: 3)
Voltage
1 (1-phase; system code: 3)
4 (3-phase; system code: 3)
Digital inputs (on request)
Up to 12
AQ1038
No. of inputs: 3 (voltage-free)
Purpose
"dmd" measurements
synchronisation.
Tariff selection: energy.
Contact status reading.
Clock synchronisation.
Contact measuring current
<8mA/ 17.5 to 25VDC
AQ1042
Number of inputs: 3 +
excitation output
Purpose
"dmd" measurements
synchronisation.
Tariff selection: energy.
Contact status reading.
Clock synchronisation.
Excitation output
16V<+Aux<24VDC Max 15mA
Contact measuring current
15mA
Common characteristics
Close contact resistance
Max 1k
Open contact resistance
Min 100k
Insulation
see "Insulation between
inputs and outputs" table
Accuracy (display, RS232, RS485)
In: 5A, If.s.: 10A
Un: see voltage ranges below
Current (A
L1
, A
L2
, A
L3
)
from 0.05In to Imax:
(@20C 5C, R.H.
75%)
(0.2%RDG+2DGT)
from 0.01In to 0.05In:
(0.5%RDG+2DGT)
Current (A
n
)
0.5% RDG (0.2 to 2 In)
@ 40 to 100 Hz
Voltage (@20C5C,R.H.
75%)
range AV5:
400/690V
L-L
AC
V
L-N
: 185 V to 460 V
V
L-L
: 320 V to 800 V
(0.2%RDG+1DGT)
range AV6:
120/208V
L-L
AC
V
L-N
: 45 V to 145 V
V
L-L
: 78 V to 250 V
(0.2%RDG+1DGT)
Includes also:
frequency, power supply
and output load influences
Frequency
0.1% RDG (40 to 440 Hz)
Active power and
0.05In to Imax, PF 1:
apparent power
(0.5%RDG+1DGT)
(@ 20C 5C, R.H.
75%)
0.01In to 0.05In, PF 1:
(1%RDG+1DGT)
0.1In to Imax, PF0.5L, PF 0.8C:
(0.6%RDG+1DGT)
0.02In to 0.1In,PF0.5L, PF 0.8C:
(1%RDG+1DGT)
Reactive power
(@ 20C 5C, R.H.
75%)
0.1In to Imax,
sen
0.5L/C: (2%RDG+1DGT)
0.05In to 0.1In, sen
0.5L/C:
(2.5%RDG+1DGT)
0.05In to Imax,
sen
1: (2%RDG+1DGT)
0.02In to 0.05In,
sen
1: (2.5%RDG+1DGT)
Energies
(@ 20C 5C, R.H.
75%)
Active: class 0.5 according
to EN62053-22, ANSI C12.20
Reactive: class 2 according
to EN62053-23, ANSI C12.1
In: 5A, Imax: 10A
0.1In: 500mA,
Start-up current: 5mA
Un: 400/690V
L-L
(AV5)
Un: 120/208V
L-L
(AV6)
Harmonic distortion
1% FS (FS: 100%)
(@ 20C 5C, R.H.
75%)
phase: 2; Imin: 5mA
RMS
;
Imax: 15Ap; Umin: 30V
RMS
;
Umax: 500Vp
Temperature drift
200ppm/C (A/V),
300ppm/C
(all the other measurements)
Sampling rate
6400 samples/s @ 50Hz
7680 samples/s @ 60Hz
Display
Graph LCD backlighted
(128x64 dots). Read-out for
the instantaneous variables:
4x4 digit
Total energies: 4x9 digit;
Partial energies: 4x9 digit
Display refresh time
100ms
Max. and min. indication
Max. 9999 (999,999,999),
Min. -9999 (999,999,999)
Front LED
Red
Blinking light in case of vir-
tual alarm
Fixed light in case of digital
output activation (alarm)
Measurements
Current, voltage, power,
energy, power factor, frequen-
cy, harmonic distortion (see
"Display Pages"). TRMS
measurement of a distorted
wave (voltage/current) .
Coupling type
Direct.
Crest factor
< 3, max 10A peak
Input impedance
400/690V
L-L
(AV5)
1.77 M
5%
120/208V
L-L
(AV6)
885 k
5%
Current
0.01
Frequency
40 to 440 Hz
Overload protection
(max values)
Continuous voltage/current
AV5: 460V
LN
, 800V
LL
/10A
AV6: 145V
LN
, 250V
LL
/10A
For 500ms: voltage/current
AV5: 800V
LN
, 1380V
LL
/36A
AV6: 240V
LN
, 416V
LL
/36A
Input specifications
4
Specifications are subject to change without notice WM5-96DS171006
WM5-96
Analogue Outputs (on request)
Number of outputs
Up to 8 (max 4 x 20mA +
4 x 10VDC or 4 x 20mA +
4 x 5mA or 8 x 10VDC or
8 x 5mA)
Accuracy (@ 25C 5C, R.H.
60%)
0.1%FS (20mA or 10VDC)
0.3%FS (5mA), FS=10mA
Range
0 to 20mA or 0 to 10 VDC
or 5mA
Scaling factor:
Programmable within the
whole range of retransmis-
sion; it allows the retrans-
mission management of all
values from: 0 and
20 mA, 0 and 10VDC,
or -5mA and +5mA
Response time
400 ms typical
(filter excluded)
Ripple
1% (according to
IEC 60688-1, EN 60688-1)
Total temperature drift
500 ppm/C
Load:
20 mADC
350
10 VDC
10k
5 mA
1400
Insulation
see "Insulation between
inputs and outputs" table
Optical communication port
According to ANSI C12.18
RS422/RS485 port
(on request)
Multidrop
bidirectional (static and
dynamic variables)
Connections
2 or 4 wires, max. distance
1000m, termination directly
on the module
Addresses
1 to 247, selectable by key-pad
Protocol
MODBUS RTU /JBUS,
Data (bidirectional)
Dynamic (reading only)
All display variables (see also
the table, "List of the variables
that can be connected to"...)
Static (writing only)
All configuration parameters,
reset of energy, activation of
digital output
Stored energy (EEPROM)
max. 999.999.999 kWh/kvarh
Data format
1-start bit, 8-data bit, no
parity/even parity,
odd parity, 1 stop bit
Baud-rate
9.6k, 19.2k, 38.4k, 115.2k bit/s
selectable bauds
Insulation
see "Insulation between
inputs and outputs" table
RS232 output (on request)
Bidirectional (static and
dynamic variables)
Connections
3 wires, max. distance 15m,
Data format
1-start bit, 8-data bit,
no parity, even parity,
odd parity, 1 stop bit
Baud-rate
9.6k bit/s
Protocol
MODBUS RTU /JBUS
Other data
as for RS422/485
Ethernet/Internet port
Protocols
Modbus TCP
IP configuration
Static IP
TCP port
Selectable (default 502)
Client connections
Max 5 simultaneously
Connections
RJ45 10/100 BaseTX
Digital outputs (on request)
Pulse type
Number of outputs
Up to 16
Type
Programmable from 0.001 to
1000 pulses per kWh/kvarh
(total and partial)
Outputs connectable to the
total and/or partial energy
meters (Wh/varh)
Pulse duration
100ms, < 120msec (ON),
100ms (OFF)
according to EN62053-31
Alarm type
Number of outputs
up to 16, independent
Alarm modes
Up alarm, down alarm, in
window alarm, out window
alarm. All of them can be
used with start up deactiva-
tion function and/or latch.
All the alarms can be con-
nected to all variables (see
the table "List of the vari-
ables that can be connected
to").
Set-point adjustment
from 0 to 100% of the
electrical scale
Hysteresis
from 0 to full scale
On-time delay
0 to 255s
Output status
Selectable; normally
de-energised and normally
energised
Min. response time
200ms, filters excluded,
Set-point on-time delay: "0 s"
Note
The 16 digital outputs
can also work as
combination of pulse
outputs and alarm
outputs.
Static (digital) outputs
(on request)
Purpose
For pulse outputs or for
alarm outputs
Signal
V
ON
1.2 VDC/ max. 100 mA
V
OFF
30 VDC max.
Insulation
see "Insulation between
inputs and outputs" table
Relay (digital) outputs
(on request)
Purpose
For alarm outputs or for pulse
outputs
Output type
Relay SPDT
AC 1-8A, 250VAC
DC 12-5A, 24VDC
AC 15-2.5A, 250VAC
DC 13-2.5A, 24VDC
Insulation
see "Insulation between
inputs and outputs" table
Output specifications
Specifications are subject to change without notice WM5-96DS171006
5
WM5-96
Data stamping
Type of data
Alarm, min, max, digital
input status, digital output
status as remote control,
resets. All events are stored
with date (dd:MM:yy) and
hour (hh:mm:ss) reference
Number of events
Up to 10,000
Data management type:
FIFO
Data storage type
Data flash
Displaying
4 variables per page
1 page that can be laid out by
the user
Up to 36 pages
Energy meters
Up to 28 pages depending on
the selected tariff mode. Dis-
playing of the consumed
energy of the previous 12
months.
Stored events
10,000 events.
Display language
Selectable:
English, Italian, French,
German, Spanish
Password
Numeric code of max 4
digits from 0 to 1000;
2 protection levels of
the programming data
1st level
Password "0": no protection
2nd level
Password from 1 to 1000:
all data are protected.
System selection
System 1
1-phase (2 wires)
System 2, unbalanced
2-phase (3 wires)
System 3, balanced
3-phase (3 wires+1CT)
System 3, unbalanced
3-phase (3 wires)
3-phase (4 wires)
Transformer ratio
CT up to 30 kA (6000 max)
VT (PT) up to 600 kV
(6000 max)
Filters
Filter operating range
0.1 to 100% of the input
electrical scale.
Filtering coefficient
1 to 255
Filter action
Display, alarms, serial outputs
(fundamental variables:
V, A, W and their derived ones).
Alarms
Working mode
"OR" or "AND" or
"OR+AND" functions (see
"Alarm parameter and logic"
page).
Freely programmable on up
to 16 alarms. The alarms
can be connected to any
variables available in the
table "List of the variables
that can be connected to"
Reset
By means of the key-pad or
of the configuration software,
it is possible to reset the
following data:
- all the min, max, dmd,
dmd-max values.
- total and partial counters.
- latch alarms.
- all the events.
Software functions
Wm5Soft
Multi-language software
(Italian, English, French,
German, Spanish) for
variable reading,
instrument calibration and
parameters programming.
The program
runs under Windows
/98/98SE/2000/NT/XP.
Working mode
Three different working
modes can be selected:
- management of local
RS232 (MODBUS);
- management of local
optical port (MODBUS);
- management of a local
RS485 network (MODBUS);
Data Storing
In pre-formatted XLS files
(Excel data base).
Data Transfer
Manual or automatic at
programmable timings.
Wm5Soft parameter programming and variable reading software
6
Specifications are subject to change without notice WM5-96DS171006
WM5-96
Analysis principle
FFT
Harmonic measurement
Current
Up to the 63
rd
harmonic
Voltage
Up to the 63
rd
harmonic
Type of harmonics
THD (V
L
1 and V
L
1-
N
)
THD odd (V
L
1 and V
L
1-
N
)
THD even (V
L
1 and V
L
1-
N
)
The same for the other phases:
L2, L3.
THD (A
L
1)
THD odd (A
L
1)
THD even (A
L
1)
The same for the other phases:
L2, L3.
Harmonic phase angle
The instrument measures the
angle between the single har-
monic of "V" and the single
harmonic of "I" of the same
order. According to the value
of the electrical angle, it is
possible to know if the distor-
tion is absorbed or generated.
Note: if the system has 3
wires the angle cannot be
measured.
Harmonic details
The harmonic contents is dis-
played as a graph showing
the whole harmonic spec-
trum. This value is also given
as a numerical information:
THD % / RMS value
THD even % / RMS value
THD odd% / RMS value
single harmonics in % /
RMS value
System
The harmonic distortion
can be measured in single-
phase, 3-wire or 4-wire
systems.
Tw: 0.02 sec@50Hz without
filter
Harmonic distortion analysis
Meters
Total
4 (9-digit)
Partial and multitariff
48 (9-digit)
Tariffs
Up to 12
Time periods
Number of periods
Up to 24 per day
Up to 100 different days per
year
Pulse output
Connectable to total and/or
partial meters (multitariff)
Energy meter recording
Consumption history by
recording of the monthly
energy meters (12 previous
months). Recording of
total and partial energy
meters.
Energy meter recording
(EEPROM)
Max.999,999,999kWh/kvarh.
Time period management
Energy Meters
Total energy meters
4 (+kWh, +kvarh, -kWh, -kvarh)
It is possible to divide each
energy meter here above listed
in 3 additional energy meters
(1 for each phase "L1-L2-L3")
Monthly energy meters
48 (energy meters for
each month: "+kWh, +kvarh,
-kWh, -kvarh")
Partial energy meters
16 (using digital inputs:
max 4 tariffs).
48 (using the internal clock:
max 12 tariffs)
Specifications are subject to change without notice WM5-96DS171006
7
WM5-96
AC/DC voltage
90 to 260V (standard)
18 to 60V (on request)
Power consumption
30VA/12W (90 to 260V)
20VA/12W (18 to 60V)
Supply specifications
industrial environment.
ANSI/IEEE C37.90-1989
(surge, withstand and fast
transient test)
Pulse voltage (1.2/50s)
EN61000-4-5
Safety standards
IEC60664, IEC61010-1
EN60664, EN61010-1
Measurement standards
IEC60688, EN60688,
EN62053-22, EN62053-23,
ANSI C12.20, ANSI C12.1
Approvals
CE, cURus and CSA
Connections 5(6) A
Screw-type
max. 2.5 mm
2
wires (2x 1.5mm
2
)
Housing
Dimensions
96x96x140 mm
Material
ABS,
self-extinguishing: UL 94 V-0
Protection degree
Front: IP65, NEMA4x,
NEMA12
Weight
Approx. 600 g
(packing included)
Operating
-10 to +45C (14 to 113F)
temperature
(R.H. < 90% non-condensing)
Limit range of operating temp.
-20 to +55C (-4 to 131F)
(R.H. <90% non-condensing)
Storage
-30 to +60C (-4 to 140F)
temperature
(R.H. < 90% non-condensing)
Installation category
III
Pollution degree
2
Altitude
up to 2000m (6560 feet) above
sea-level
Insulation reference
voltage
300 V
RMS
to ground (AV5 input)
Dielectric strength
4kVAC
RMS
(for 1 min)
Noise Rejection
CMRR
100 dB, 48 to 62 Hz
EMC
Emissions
EN61000-6-3, EN60688
residential environment,
commerce and light industry
Immunity
EN61000-6-2
General Specifications
Revenue approval settings
The access to the programming parameters via front key pad and/or serial commu-
nication ports is locked.
The front key pad (up and down keys) allows the displaying of the variables only,
while the communication ports allows the transmission of the variables only
.
A proper "instrument settings" form must be filled up by the user before equipment
supplying.
WM5-96 is supplied with the desired modules plugged and sealed in the proper slots.
WM5-96 fulfils:
the ANSI/IEEE C12.20-1998 requirements;
the CAN3-C17-M84 requirements;
and can be certified according to:
C12.20-1998, class 0.5 (independent labs);
AE-0924 Industry Canada Approval.
8
Specifications are subject to change without notice WM5-96DS171006
WM5-96
Alarm parameters and logic
ON alarm (SET 1)
OFF alarm (SET2)
Up alarm
SET 1 > SET 2
Off alarm (SET 1)
On alarm (SET 2)
Down alarm
SET 2 < SET 1
In windows alarm
In alarm between
SET 1 and SET 2
In alarm 1 (SET 1)
Out windows alarm with
start up deactivation
In alarm over SET 1 and
below SET 2
Out alarm 1 (SET 1)
Activation of the alarm function
AND/OR logical alarm examples:
A: AND
B: AND
C: AND
A: AND
B: AND
C: AND
A: AND
B: AND
C: AND
A: OR
B: OR
C: OR
A: OR
B: OR
C: OR
A: OR
B: OR
C: OR
A: OR
B: OR
C: AND
D: AND
A: OR
B: OR
C: AND
D: AND
A: OR
B: OR
C: AND
D: AND
- Block enable.
- Controlled variable (VLN, ...).
- Alarm type (up, down, window int,
window ext).
- Activation function.
- Latch
- SET 1.
- SET 2.
- ON delay.
- OFF delay
- Logical function (AND, OR).
- Digital output (1 to 16).
Note: any alarm working mode can be linked to the "Activation" function which disables only the first alarm at the power on
of the instrument. All the alarms can be used with the latch function.
AND
OR
OR+AND
8
8
A, B, C... up to 16
parameter control
blocks.
In alarm 2 (SET 2)
(SET 2)
Specifications are subject to change without notice WM5-96DS171006
9
WM5-96
Function Description
Figure A
The sign of measured quant-
ity and output quantity re-
mains the same. The output
quantity is proportional to the
measured quantity.
Input and output scaling capability. Working of the analogue outputs (y) versus input variables (x)
Figure B
The sign of measured quant-
ity and output quantity
changes simultaneously. The
output quantity is proportion-
al to the measured quantity.
Figure C
The sign of measured quant-
ity and output quantity re-
mains the same. On the
range X0...X1, the output
quantity is zero. The range
X1...X2 is delineated on the
entire output range Y0 =
Y1...Y2 and thus presented in
strongly expanded form.
Figure F
The sign of the measured
quantity remains the same,
the one of the output quantity
changes as the measured
quantity leaves range X0...X1
and passes to range X1...X2
and vice versa.
Figure E
The sign of the measured
quantity changes but the one
of the output quantity
remains the same. The output
quantity steadily increases
from value X1 to value X2 of
the measured quantity.
Figure D
The sign of measured quant-
ity and output quantity re-
mains the same. With the
measured quantity being
zero, the output quantity
already has the value
Y1 = 0.2 Y2.
Live zero output.
0
50 A 100 A
0
10 mA 20 mA
-100 kW
0
100 kW
-5 mA
0
+5 mA
80 V
100 V
120 V
0
5 mA 10
mA
0
50 A 100
A
4
12 mA 20
mA
-100 kW
0
100 kW
0
10 mA
20 mA
0
50 A 100
A
-5 mA
0
+5 mA
Insulation between inputs and outputs
Meas. /digi-
tal inputs
Relay
output
Open collec-
tor output
Analogue out.
10V, 20mA
Analogue out.
5mA
AR1034
AR2040
AR1039
Power Supply
90-260VAC/DC
Power Supply
18-60VAC/DC
Meas. /digital
inputs
-
4kV
4kV
2kV
2kV
4kV
2kV
4kV
4kV
4kV
Relay output
4kV
4kV (*)
4kV
4kV
4kV
4kV
4kV
4kV
4kV
4kV
Open coll.out.
4kV
4kV
4kV (*)
4kV
4kV
4kV
4kV
4kV
4kV
4kV
Analogue out.
10V, 20mA
2kV
4kV
4kV
4kV (*)
4kV
4kV
4kV
4kV
4kV
4kV
Analogue out.
5mA
2kV
4kV
4kV
4kV
200V (**)
4kV
4kV
4kV
4kV
4kV
AR1034
4kV
4kV
4kV
4kV
4kV
-
-
4kV
4kV
4kV
AR2040
2kV
4kV
4kV
4kV
4kV
-
-
4kV
4kV
4kV
AR1039
4kV
4kV
4kV
4kV
4kV
4kV
4kV
-
4kV
4kV
90-260VAC/DC
4kV
4kV
4kV
4kV
4kV
4kV
4kV
4kV
-
-
18-60VAC/DC
4kV
4kV
4kV
4kV
4kV
4kV
4kV
4kV
-
-
NOTE: In case of fault of first insulation the current from the measuring inputs to the ground is lower than 2 mA.
(*) The given insulation is granted among outputs plugged in different slots. The modules equipped with two or four outputs
have therefore non insulation among the outputs. (**) Insulation between the 2 outputs of the same module is 200V for 1 min.
10
Specifications are subject to change without notice WM5-96DS171006
WM5-96
System variables
Equivalent three-phase voltage
Voltage asymmetry
Three-phase reactive power
Neutral current
Three-phase active power
Three-phase apparent power
Used calculation formulas
Accuracy
kWh, accuracy (RDG) depending on the current
Error
10A (Imax)
10A (Imax)
5A (In)
5A (In)
0.25A
(0.05In)
0.5A
(0.1In)
0.05A
(0.01In)
0.1A
(0.02In)
+1.0%
Class 0.5 accuracy limits (Active energy) EN62053-21
5(10A) Start-up current: 5mA
kvarh, accuracy (RDG) depending on the current
Error
Class 2 accuracy limits (Reactive energy) EN62053-23
5(10A) Start-up current: 5mA
PF=1
PF=L0.5
or C0.8
10A (Imax)
10A (Imax)
5A (In)
5A (In)
0.25A
(0.05In)
0.5A
(0.1In)
0.1A
(0.02In)
0.25A
(0.05In)
sin
=1
sin
=0.5
Phase variables
Instantaneous effective voltage
Instantaneous active power
Instantaneous power factor
Instantaneous effective current
Instantaneous apparent power
Instantaneous reactive power
Energy metering
Where:
i= considered phase (L1, L2 or L3)
P= active power; Q= reactive power;
t
1
, t
2
=starting and ending time points
of consumption recording; n= time
unit;
t= time interval between two
successive power measurements;
n
1
, n
2
= starting and ending discrete
time points of power recording
An = A
L1
+A
L2
+A
L3
+0.5%
PF=1
PF=L0.5
or C0.8
+2.5%
+2%
-1.0%
-0.5%
-2.5%
-2%
-
=
L L
L L
L L
L L
V
V
V
A S Y
)
(
m in
m a x
Three-phase power factor
(TPF)
-
=
LN
LN
LN
LN
V
V
V
ASY
)
(
min
max
Class 0.5
Class 2
+0.6%
-0.6%
sin
=1
Code
Description
Slot A
Slot B
Slot C
Slot D
AO1058
1 relay output
A0
B0
C0
D0
AO1059
1 open coll. output A0
B0
C0
D0
AO1035
2 relay outputs
A0 A1
B0 B1
C0 C1
D0 D1
AO1036
2 open coll. outputs A0 A1
B0 B1
C0 C1
D0 D1
AO1037
4 open coll. outputs A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 D1 D2 D3 D4
Digital outputs important note
The grey-marked digital outputs are acti-
vated for a while during the instrument
start-up, therefore they are not suggested
for pulse output purpose.
Specifications are subject to change without notice WM5-96DS171006
11
WM5-96
Analogue outputs (all listed variables with the only exception of energies), alarm outputs (all listed variables with the
only exception of energies), pulse outputs (only energies), communication (all listed variables).
No
Variable
1-phase
2-ph. 3-wire 3-ph. 4-wire 3-ph. 3-wire 3-ph. 4-wire
Notes
system
system
bal. (1 CT) unbal. sys.
unbal. sys.
1
V L1
x
x
x
o
x
2
V L2
o
x
x
o
x
3
V L3
o
o
x
o
x
4
V L-N sys
o
x
x
o
x
Sys = system =

5
V L1-2
o
x
x
x
x
6
V L2-3
o
o
x
x
x
7
V L3-1
o
o
x
x
x
8
V L-L sys
o
o
x
x
x
Sys = system =

9
A L1
x
x
x
x
x
10
A L2
o
x
x
x
x
11
A L3
o
o
x
x
x
12
An
o
x
x
o
x
An=neutral current
13
W L1
x
x
x
x
x
14
W L2
o
x
x
x
x
15
W L3
o
o
x
x
x
16
W sys
o
x
x
x
x
17
var L1
x
x
x
x
x
18
var L2
o
x
x
x
x
19
var L3
o
o
x
x
x
20
var sys
o
x
x
x
x
Sys = system =

21
VA L1
x
x
x
x
x
22
VA L2
o
x
x
x
x
23
VA L3
o
o
x
x
x
24
VA sys
o
x
x
x
x
Sys = system =

25
PF L1
x
x
x
x
x
26
PF L2
o
x
x
x
x
27
PF L3
o
o
x
x
x
28
PF sys
o
x
x
x
x
Sys = system =

29
Hz
x
x
x
x
x
30
ASY VL-N
o
x
x
o
x
Asymmetry of phase-neutral
31
ASY VL-L
o
o
x
x
x
Asymmetry of phase-phase
32
THD V1
x
x
x
o
x
33
THD V2
o
x
x
o
x
34
THD V3
o
o
x
o
x
35
THD V1-2
o
x
x
x
x
36
THD V2-3
o
o
x
x
x
37
THD V3-1
o
o
x
x
x
38
THD A1
x
x
x
x
x
39
THD A2
o
x
x
x
x
40
THD A3
o
o
x
x
x
41
THDo V1
x
x
x
o
x
42
THDo V2
o
x
x
o
x
43
THDo V3
o
o
x
o
x
44
THDo V1-2
o
x
x
x
x
45
THDo V2-3
o
o
x
x
x
46
THDo V3-1
o
o
x
x
x
47
THDo A1
x
x
x
x
x
48
THDo A2
o
x
x
x
x
49
THDo A3
o
o
x
x
x
50
THDe V1
x
x
x
o
x
51
THDe V2
o
x
x
o
x
52
THDe V3
o
o
x
o
x
53
THDe V1-2
o
x
x
x
x
54
THDe V2-3
o
o
x
x
x
55
THDe V3-1
o
o
x
x
x
56
THDe A1
x
x
x
x
x
57
THDe A2
o
x
x
x
x
58
THDe A3
o
o
x
x
x
59
Phase seq.
o
o
x
x
x
Phase sequence
(x) = available
(o) = not available
List of the variables that can be connected to:
WM5-96
12
Specifications are subject to change without notice WM5-96DS171006
WM5-96
Display variables in three-phase systems, 4-wire connections
No
1st variable
2nd variable
3rd variable
4th variable Note
0
Selectable
Selectable
Selectable
See note
kWh + kvarh meters + W% bargraph
1
V L1
V L2
V L3
V L-N sys
instant.-min-max-dmd-max dmd
2
V L1-2
V L2-3
V L3-1
V L-L sys
instant.-min-max-dmd-max dmd
3
A L1
A L2
A L3
An
instant.-min-max-dmd-max dmd
4
W L1
W L2
W L3
W sys
instant.-min-max-dmd-max dmd
5
var L1
var L2
var L3
var sys
instant.-min-max-dmd-max dmd
6
VA L1
VA L2
VA L3
VA sys
instant.-min-max-dmd-max dmd
7
PF L1
PF L2
PF L3
PF sys
instant.-min-max-dmd-max dmd
8
V L1
A L1
PF L1
W L1
instant.-min-max-dmd-max dmd
9
V L2
A L2
PF L2
W L2
instant.-min-max-dmd-max dmd
10
V L3
A L3
PF L3
W L3
instant.-min-max-dmd-max dmd
11
V L-L sys
ASY V L-L
Hz
An
instant.-min-max-dmd-max dmd
12
V L-N sys
ASY V L-N
Hz
An
instant.-min-max-dmd-max dmd
13
W sys
var sys
PF sys
VA sys
instant.-min-max-dmd-max dmd
14
THD VL1 tot
THD VL2 tot
THD VL3 tot
instant.-min-max-dmd-max dmd
15
THD VL1 odd
THD VL2 odd
THD VL3 odd
instant.-min-max-dmd-max dmd
16
THD VL1 even
THD VL2 even
THD VL3 even
instant.-min-max-dmd-max dmd
17
THD VL1-2 tot
THD VL2-3 tot
THD VL3-1 tot
instant.-min-max-dmd-max dmd
18
THD VL1-2 odd
THD VL2-3 odd
THD VL3-1 odd
instant.-min-max-dmd-max dmd
19
THD VL1-2 even
THD VL2-3 even
THD VL3-1 even
instant.-min-max-dmd-max dmd
20
THD AL1 tot
THD AL2 tot
THD AL3 tot
instant.-min-max-dmd-max dmd
21
THD AL1 odd
THD AL2 odd
THD AL3 odd
instant.-min-max-dmd-max dmd
22
THD AL1 even
THD AL2 even
THD AL3 even
instant.-min-max-dmd-max dmd
23
Histogram FFT V1 (THD, THDo, THDe, Single harmonic)
24
Histogram FFT V2 (THD, THDo, THDe, Single harmonic)
25
Histogram FFT V3 (THD, THDo, THDe, Single harmonic)
26
Histogram FFT V1-2 (THD, THDo, THDe, Single harmonic)
27
Histogram FFT V2-3 (THD, THDo, THDe, Single harmonic)
28
Histogram FFT V3-1 (THD, THDo, THDe, Single harmonic)
29
Histogram FFT A1 (THD, THDo, THDe, Single harmonic)
30
Histogram FFT A2 (THD, THDo, THDe, Single harmonic)
31
Histogram FFT A3 (THD, THDo, THDe, Single harmonic)
32
Digital input status
33
Digital output status
34
Energy meters
35
Events
36
Alarms status
37
Info
38
Info
39
Info
Display pages
Specifications are subject to change without notice WM5-96DS171006
13
WM5-96
WM5-96
WM5-96
L1
L2
L3
2
9
10
1
8
L1
L2
L3
2
9
10
1
8
L1
L2
L3
N
2
7
1
8
10
9
CT and VT connections (3-wire system)
Direct connection (3-wire system)
CT and VT connections (4-wire system)
Fig. 6
Fig. 7
3-phase, 3 and 4-wire input connections - Balanced load (3P)
Wiring diagrams
L1
L1
N
N
L3
L3
L2
L2
U
1
1
3
3
5
5
2
2
4
4
6
6
I
I
L1
L1
L2
L2
L3
L3
8
8
7
7
10
10
9
9
1
6
9
2
3
4
5
8
7
10
L1
N
2
7
1
8
10
9
L1
N
2
7
1
8
10
9
Direct connection
CT connection
Fig. 1
Fig. 2
2-phase, 3-wire input connections (2P)
L1
N
2
7
1
8
10
9
L1
L2
N
2
7
1
8
4
3
9
L1
L2
N
2
7
1
8
4
3
9
Direct connection
CT and VT connections
CT connection
Fig. 3
Fig. 4
Fig. 5
1-phase, 2-wire input connections (1P)
Fig. 8
14
Specifications are subject to change without notice WM5-96DS171006
WM5-96
Wiring diagrams (cont.)
3-phase, 3-wire input connections - Unbalanced load (3P)
L1
L2
L3
2
9
10
1
3
4
5
6
8
Direct connection (3-wire system)
L1
L2
L3
2
9
10
1
3
4
5
6
8
L1
L2
L3
2
9
10
1
3
4
5
6
8
L1
L2
L3
2
9
10
1
3
4
5
6
8
CT and VT connections (3-wire system)
Direct connection (4-wire system)
CT connection (4-wire system)
Fig. 10
Fig. 9
Fig. 11
Fig. 12
Fig. 13
L1
L2
L3
2
9
10
1
3
4
5
6
8
CT connection (3-wire system)
3-phase, 4 wires input connections - Unbalanced load (3p+N)
L1
L2
L3
N
2
9
10
7
1
3
4
5
6
8
L1
L2
L3
N
2
9
10
7
1
3
4
5
6
8
ARON connection (3-wire system)
ARON and VT connections (3-wire system)
Fig. 15
Fig. 16
L1
L1
N
N
L3
L3
L2
L2
U
1
1
3
3
5
5
2
2
4
4
6
6
I
I
L1
L1
L2
L2
L3
L3
8
8
7
7
10
10
9
9
1
6
9
2
3
4
5
8
7
10
3-phase, 3-wire input connections ARON (3P)
L1
L2
L3
N
2
9
10
7
1
3
4
5
6
8
CT and VT connections (4-wire system)
Fig. 14
Specifications are subject to change without notice WM5-96DS171006
15
WM5-96
WM5-96
WM5-96
RS422/485 NOTE: additional devices provided with RS422/485 (that is RS 1, 2, 3...N) are connected in parallel. The termina-
tion of the serial output is carried out only on the last instrument of the network, by means of a jumper between (RX+) and (T).
Wiring diagrams: digital input modules
AQ1042
Connection by
means of NPN
transistors.
AQ1042
Connection by
means of con-
tacts.
AQ1038
Connection by
means of con-
tacts.
AQ1042
Connection by
means of PNP
transistors.
Wiring diagrams (optional modules)
cd 8010562
analog (0)
analog (0)
analog (1)
analog (1)
A
+
+
A
+
+
1
0
(-mA)(+V)
(-mA)(+V)
(+mA)(-V)
(+mA)(-V)
(+mA)(-V)
(+mA)(-V)
(-mA)(+V)
(-mA)(+V)
AO1037 4-open collector output connection:
This wiring diagram is valid also for the open
collector module with one or two outputs.
The load resistances (RC) must be designed so
that the close contact current is lower than
100mA; the VDC voltage must be lower than or
equal to 30VDC.
AR1034/AR2040
4-wire connection of RS485 serial port
AR1034/AR2040
2-wire connection of RS485 serial port
AO1035
2 relay outputs
AO1058
1 relay output
AO2052
2 analogue
outputs (+/-5mA)
AO2050
2 analogue
outputs (0-20mA)
cd 8010562
analog (0)
analog (0)
analog (1)
analog (1)
V
-
-
V
-
-
1
0
(-mA)(+V)
(-mA)(+V)
(+mA)(-V)
(+mA)(-V)
(+mA)(-V)
(+mA)(-V)
(-mA)(+V)
(-mA)(+V)
AO1051
2 analogue
outputs (10V)
S
E
R
I
A
L
C
O
N
V
E
R
T
E
R
S
E
R
I
A
L
C
O
N
V
E
R
T
E
R
DC
DC
0
DC
DC
16
Specifications are subject to change without notice WM5-96DS171006
WM5-96
ARM
Powered
PRG
measures
S
S
R
!
R
AL
WM5-96
Smart Power Quality Analyzer
Class 0.2 A/V
and
- to program values
- to select functions
- to scroll display pages
2. Display
Instantaneous measurements:
- 4 digits (max display 9999)
Energies:
- 9 digits (max display 999 999 999).
Alphanumeric indications by means of LCD display for:
- Display of configuration parameters
- All measuring variables.
3. LED
Alarm LED.
4. Optical Port
For data reading and programming (or pulse output).
w
w
v
v
Dimensions
Front panel description
1
1. Key-pad
Set-up, programming and display parameters are easily
controlled by the 3 push-buttons.
-
to enter programming and to confirm password.
S
2
4
3
24mm
5
m
m
Specifications are subject to change without notice WM5-96DS171006
17
WM5-96
WM5-96
WM5-96
WM5-96
Modules
AP1021
18-60VAC/DC power supply
AP1020
90-260 VAC/DC power supply
cd 8010582
analog (0)
analog (0)
(-mA)(+V)
(-mA)(+V)
analog (1)
analog (1)
(+mA)(-V)
(+mA)(-V)
(+mA)(-V)
(+mA)(-V)
(-mA)(+V)
(-mA)(+V)
AO2050
(20mADC)
AO2051
(10VDC)
AR1034
AR2040
RS485 port
AO1035
Dual relay output
AO1059
Single open collector
output
AO1036
Dual open collector
output
AO1058
Single relay output
AQ1038
3 digital inputs
AR1039
RS232 port + RTC
Dual analogue output modules
Digital output modules
Other input/output modules
Power supply modules
AO1037
4 open collector
outputs
AQ1042
3 digital inputs + aux
AO2052
(+/-5mADC)